4
(cabinet width = 560mm)
note: measurements exclude
the insulating blanket
495mm
405mm
550mm
672mm
Dimension
X
325mm
130mm
70mm
Metro fireplace inserts are designed to be installed directly
onto a concrete base. An insulating floor protector is required
toprojectinfrontoftheMetroandmustextendaminimumof
200mm to each side of the door opening making the minimum
floor protector width 825mm. The minimum floor protector
projectionforwardofthecavitywallisillustratedinthekey
below. The floor protector construction must be a minimum
thickness of 26mm Eterpan, or alternative insulating material
of equivalent insulation properties, to achieve the minimum
insulation required. Finish with a non combustible tile or similar.
Floor protector requirements
Position the Metro ECO Smart Insert which is still attached to its
wooden pallet directly in front of the fireplace cavity with the
rear of the insert facing the fireplace opening. The fireplace
insert assembly is bolted to the wooden pallet through its base
panelattwopointsbeingeachfrontcorner.Removeboth
screws and slide the insert into the fireplace cavity taking care
not to mark the floor protector. Discard the pallet.
1. Attach the fascia with the four longer screws that were
supplied in the plastic bag taking care that the air control
lever passes through the slot provided in the fascia.
Centralise and level the fascia on the fireplace insert
door and secure the four screws.
2. Applying pressure to the door or inside the fireplace
firebox (not the fascia) carefully manoeuvre the Metro
untiltherearofthefasciaisjusttouchingthefrontfaceof
the fireplace surround. Taking care not to move the
fireplace insert, remove the fascia and mark the position
of the fireplace insert onto the fireplace base.
3. Using a masonry drill, drill into the chimney base through
the two slots which the fireplace insert was secured to
the pallet through, check to ensure the fireplace insert
hasn’t moved and secure using suitable masonry anchors
to comply with the seismic restraint provisions of the
standard.
4. Removethetopbafefrominsidethereplaceinsertand
the removable cabinet top. Check that the flue stub of the
fireplace insert is in line by looking down the chimney, if
not a stainless steel offset or flexi flue will be required.
5. Following the instruction sheet supplied with the flue
system,proceedandttheuewithalljointssealedand
riveted with a minimum of three stainless steel or monel
rivetsoneachjoint.
6. With the flue pipe in position and sealed with a high
temperature fire cement into the flue stub, drill through the
hole provided in the front of the flue stub into the stainless
steel flue pipe and secure with the 6mm bolt and nut
supplied in the plastic bag.
7. Retthetopbafeintotherebox’supperchamber.
Repositiontheremovablecabinettopensuringitis
correctly fitting as detailed on page 2 and secure in its
upperpositionifpossible.Note,iftheadjustableheight
top can be raised slightly but not fully to its upper position,
additional holes should be drilled to enable the top to be
raised to this level.
8. Using a suitable rated insulation (fibretex 450 or similar)
pack any gap that exists between the sides and top of the
fireplace insert cabinet and fireplace surround.
- Do NOT block off the lower convection slots in the base of
the outer wrap (all three sides).
9. Re-attachthefascia,centraliseandlevelwiththedoor
and ensure the air control is moving freely and secure all
four screws.
10. Locate the air control knob which is included in the plastic
bag and carefully work it onto the air control lever.
The Metro is now fully installed and ready for operation but
it is preferable to defer lighting the fire for a day or two if
possibletoallowsealantusedintheuepipejointstoairdry.
Alternatively it is recommended you burn 2-3 sheets of loosely
crumpled newspaper at a time, approx once every hour over
a 6-8 hour period.